Add a sample self defined modbus function library (not complete)
This commit is contained in:
@@ -11,10 +11,10 @@ namespace Modbus.Net.Tests
|
||||
public void GetUtility()
|
||||
{
|
||||
BaseMachine<int, int> baseMachine = new ModbusMachine<int, int>(1, ModbusType.Tcp, "192.168.3.12", null, true, 2, 0);
|
||||
var utility = baseMachine.GetUtility<IUtilityMethodTime>();
|
||||
var utility = baseMachine.GetUtility<IUtilityMethodData>();
|
||||
var methods = utility.GetType().GetRuntimeMethods();
|
||||
Assert.AreEqual(methods.FirstOrDefault(method => method.Name == "GetTimeAsync") != null, true);
|
||||
Assert.AreEqual(methods.FirstOrDefault(method => method.Name == "SetTimeAsync") != null, true);
|
||||
Assert.AreEqual(methods.FirstOrDefault(method => method.Name == "GetDataAsync") != null, true);
|
||||
Assert.AreEqual(methods.FirstOrDefault(method => method.Name == "SetDataAsync") != null, true);
|
||||
baseMachine.Disconnect();
|
||||
}
|
||||
|
||||
@@ -22,10 +22,10 @@ namespace Modbus.Net.Tests
|
||||
public async Task InvokeUtility()
|
||||
{
|
||||
BaseMachine<int, int> baseMachine = new ModbusMachine<int, int>(1, ModbusType.Tcp, "192.168.3.12", null, true, 2, 0);
|
||||
var success = await baseMachine.BaseUtility.GetUtilityMethods<IUtilityMethodTime>().SetTimeAsync(DateTime.Now);
|
||||
var success = await baseMachine.BaseUtility.GetUtilityMethods<IUtilityMethodData>().SetDatasAsync("4X 1", new object[] {(byte)11});
|
||||
Assert.AreEqual(success, true);
|
||||
var time = await baseMachine.BaseUtility.GetUtilityMethods<IUtilityMethodTime>().GetTimeAsync();
|
||||
Assert.AreEqual((time.Datas.ToUniversalTime() - DateTime.Now.ToUniversalTime()).Seconds < 10, true);
|
||||
var datas = await baseMachine.BaseUtility.GetUtilityMethods<IUtilityMethodData>().GetDatasAsync("4X 1", 1);
|
||||
Assert.AreEqual(datas.Datas[0], 11);
|
||||
baseMachine.Disconnect();
|
||||
}
|
||||
|
||||
|
||||
Reference in New Issue
Block a user