Merge branch 'master' of https://github.com/parallelbgls/Modbus.Net.git
This commit is contained in:
@@ -4,6 +4,9 @@ using System.Threading.Tasks;
|
||||
|
||||
namespace Modbus.Net.Modbus
|
||||
{
|
||||
/// <summary>
|
||||
/// 变量功能码
|
||||
/// </summary>
|
||||
internal enum ModbusProtocalVariableFunctionCode : byte
|
||||
{
|
||||
ReadVariable = 20,
|
||||
@@ -39,6 +42,9 @@ namespace Modbus.Net.Modbus
|
||||
WriteMultiRegister = 16
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Modbus协议
|
||||
/// </summary>
|
||||
public abstract class ModbusProtocal : BaseProtocal
|
||||
{
|
||||
protected ModbusProtocal(byte slaveAddress, byte masterAddress) : base(slaveAddress, masterAddress)
|
||||
@@ -58,7 +64,7 @@ namespace Modbus.Net.Modbus
|
||||
|
||||
#region 读PLC数据
|
||||
|
||||
public class ReadDataModbusInputStruct : InputStruct
|
||||
public class ReadDataModbusInputStruct : IInputStruct
|
||||
{
|
||||
public ReadDataModbusInputStruct(byte slaveAddress, string startAddress, ushort getCount,
|
||||
AddressTranslator addressTranslator)
|
||||
@@ -79,7 +85,7 @@ namespace Modbus.Net.Modbus
|
||||
public ushort GetCount { get; }
|
||||
}
|
||||
|
||||
public class ReadDataModbusOutputStruct : OutputStruct
|
||||
public class ReadDataModbusOutputStruct : IOutputStruct
|
||||
{
|
||||
public ReadDataModbusOutputStruct(byte slaveAddress, byte functionCode,
|
||||
int dataCount, byte[] dataValue)
|
||||
@@ -101,14 +107,14 @@ namespace Modbus.Net.Modbus
|
||||
|
||||
public class ReadDataModbusProtocal : ProtocalUnit
|
||||
{
|
||||
public override byte[] Format(InputStruct message)
|
||||
public override byte[] Format(IInputStruct message)
|
||||
{
|
||||
var r_message = (ReadDataModbusInputStruct) message;
|
||||
return Format(r_message.SlaveAddress, r_message.FunctionCode,
|
||||
r_message.StartAddress, r_message.GetCount);
|
||||
}
|
||||
|
||||
public override OutputStruct Unformat(byte[] messageBytes, ref int pos)
|
||||
public override IOutputStruct Unformat(byte[] messageBytes, ref int pos)
|
||||
{
|
||||
var slaveAddress = BigEndianValueHelper.Instance.GetByte(messageBytes, ref pos);
|
||||
var functionCode = BigEndianValueHelper.Instance.GetByte(messageBytes, ref pos);
|
||||
@@ -130,7 +136,7 @@ namespace Modbus.Net.Modbus
|
||||
|
||||
#region 写PLC数据
|
||||
|
||||
public class WriteDataModbusInputStruct : InputStruct
|
||||
public class WriteDataModbusInputStruct : IInputStruct
|
||||
{
|
||||
public WriteDataModbusInputStruct(byte slaveAddress, string startAddress, object[] writeValue,
|
||||
AddressTranslator addressTranslator)
|
||||
@@ -159,7 +165,7 @@ namespace Modbus.Net.Modbus
|
||||
public byte[] WriteValue { get; }
|
||||
}
|
||||
|
||||
public class WriteDataModbusOutputStruct : OutputStruct
|
||||
public class WriteDataModbusOutputStruct : IOutputStruct
|
||||
{
|
||||
public WriteDataModbusOutputStruct(byte slaveAddress, byte functionCode,
|
||||
ushort startAddress, ushort writeCount)
|
||||
@@ -184,7 +190,7 @@ namespace Modbus.Net.Modbus
|
||||
/// </summary>
|
||||
public class WriteDataModbusProtocal : ProtocalUnit
|
||||
{
|
||||
public override byte[] Format(InputStruct message)
|
||||
public override byte[] Format(IInputStruct message)
|
||||
{
|
||||
var r_message = (WriteDataModbusInputStruct) message;
|
||||
var functionCode = r_message.FunctionCode;
|
||||
@@ -201,7 +207,7 @@ namespace Modbus.Net.Modbus
|
||||
return formattingBytes;
|
||||
}
|
||||
|
||||
public override OutputStruct Unformat(byte[] messageBytes, ref int flag)
|
||||
public override IOutputStruct Unformat(byte[] messageBytes, ref int flag)
|
||||
{
|
||||
var slaveAddress = BigEndianValueHelper.Instance.GetByte(messageBytes, ref flag);
|
||||
var functionCode = BigEndianValueHelper.Instance.GetByte(messageBytes, ref flag);
|
||||
@@ -216,7 +222,7 @@ namespace Modbus.Net.Modbus
|
||||
|
||||
#region 读PLC时间
|
||||
|
||||
public class GetSystemTimeModbusInputStruct : InputStruct
|
||||
public class GetSystemTimeModbusInputStruct : IInputStruct
|
||||
{
|
||||
public GetSystemTimeModbusInputStruct(byte slaveAddress)
|
||||
{
|
||||
@@ -235,7 +241,7 @@ namespace Modbus.Net.Modbus
|
||||
public ushort GetCount { get; }
|
||||
}
|
||||
|
||||
public class GetSystemTimeModbusOutputStruct : OutputStruct
|
||||
public class GetSystemTimeModbusOutputStruct : IOutputStruct
|
||||
{
|
||||
public GetSystemTimeModbusOutputStruct(byte slaveAddress, byte functionCode,
|
||||
byte writeByteCount, ushort year, byte day, byte month, ushort hour, byte second, byte minute,
|
||||
@@ -261,14 +267,14 @@ namespace Modbus.Net.Modbus
|
||||
/// </summary>
|
||||
public class GetSystemTimeModbusProtocal : ProtocalUnit
|
||||
{
|
||||
public override byte[] Format(InputStruct message)
|
||||
public override byte[] Format(IInputStruct message)
|
||||
{
|
||||
var r_message = (GetSystemTimeModbusInputStruct) message;
|
||||
return Format(r_message.SlaveAddress, r_message.FunctionCode,
|
||||
r_message.StartAddress, r_message.GetCount);
|
||||
}
|
||||
|
||||
public override OutputStruct Unformat(byte[] messageBytes, ref int flag)
|
||||
public override IOutputStruct Unformat(byte[] messageBytes, ref int flag)
|
||||
{
|
||||
var slaveAddress = BigEndianValueHelper.Instance.GetByte(messageBytes, ref flag);
|
||||
var functionCode = BigEndianValueHelper.Instance.GetByte(messageBytes, ref flag);
|
||||
@@ -289,7 +295,7 @@ namespace Modbus.Net.Modbus
|
||||
|
||||
#region 写PLC时间
|
||||
|
||||
public class SetSystemTimeModbusInputStruct : InputStruct
|
||||
public class SetSystemTimeModbusInputStruct : IInputStruct
|
||||
{
|
||||
public SetSystemTimeModbusInputStruct(byte slaveAddress, DateTime time)
|
||||
{
|
||||
@@ -332,7 +338,7 @@ namespace Modbus.Net.Modbus
|
||||
public ushort Millisecond { get; }
|
||||
}
|
||||
|
||||
public class SetSystemTimeModbusOutputStruct : OutputStruct
|
||||
public class SetSystemTimeModbusOutputStruct : IOutputStruct
|
||||
{
|
||||
public SetSystemTimeModbusOutputStruct(byte slaveAddress, byte functionCode,
|
||||
ushort startAddress, ushort writeCount)
|
||||
@@ -357,7 +363,7 @@ namespace Modbus.Net.Modbus
|
||||
/// </summary>
|
||||
public class SetSystemTimeModbusProtocal : ProtocalUnit
|
||||
{
|
||||
public override byte[] Format(InputStruct message)
|
||||
public override byte[] Format(IInputStruct message)
|
||||
{
|
||||
var r_message = (SetSystemTimeModbusInputStruct) message;
|
||||
return Format(r_message.SlaveAddress, r_message.FunctionCode,
|
||||
@@ -366,7 +372,7 @@ namespace Modbus.Net.Modbus
|
||||
r_message.Month, r_message.Hour, r_message.Second, r_message.Minute, r_message.Millisecond);
|
||||
}
|
||||
|
||||
public override OutputStruct Unformat(byte[] messageBytes, ref int flag)
|
||||
public override IOutputStruct Unformat(byte[] messageBytes, ref int flag)
|
||||
{
|
||||
var slaveAddress = BigEndianValueHelper.Instance.GetByte(messageBytes, ref flag);
|
||||
var functionCode = BigEndianValueHelper.Instance.GetByte(messageBytes, ref flag);
|
||||
|
||||
Reference in New Issue