namespace Modbus.Net.Modbus.NA200H
{
/// <summary>
/// 南大奥拓NA200H专用AddressFormater
/// </summary>
public class AddressFormaterNA200H : AddressFormater
{
/// <summary>
/// 格式化地址
/// </summary>
/// <param name="area">地址区域</param>
/// <param name="address">地址</param>
/// <returns>格式化的地址字符串</returns>
public override string FormatAddress(string area, int address)
{
return area + " " + address;
}
/// <summary>
/// 格式化地址
/// </summary>
/// <param name="area">地址区域</param>
/// <param name="address">地址</param>
/// <param name="subAddress">比特位地址</param>
/// <returns>格式化的地址字符串</returns>
public override string FormatAddress(string area, int address, int subAddress)
{
return area + " " + address + "." + subAddress;
}
}
}

View File

@@ -0,0 +1,262 @@
using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace Modbus.Net.Modbus.NA200H
{
/// <summary>
/// 南大奥拓NA200H数据单元翻译器
/// </summary>
public class AddressTranslatorNA200H : ModbusTranslatorBase
{
/// <summary>
/// 读功能码
/// </summary>
protected Dictionary<string, AreaOutputDef> ReadFunctionCodeDictionary;
/// <summary>
/// 功能码翻译至标准Modbus地址位置
/// </summary>
protected Dictionary<string, int> TransDictionary;
/// <summary>
/// 写功能码
/// </summary>
protected Dictionary<(string, bool), AreaOutputDef> WriteFunctionCodeDictionary;
/// <summary>
/// 构造器
/// </summary>
public AddressTranslatorNA200H()
{
TransDictionary = new Dictionary<string, int>
{
{"Q", 0},
{"M", 10000},
{"N", 30000},
{"I", 0},
{"S", 10000},
{"IW", 0},
{"SW", 5000},
{"MW", 0},
{"QW", 20000},
{"NW", 21000}
};
ReadFunctionCodeDictionary = new Dictionary<string, AreaOutputDef>
{
{
"Q",
new AreaOutputDef
{
Code = (int) ModbusProtocolReadDataFunctionCode.ReadCoilStatus,
AreaWidth = 0.125
}
},
{
"M",
new AreaOutputDef
{
Code = (int) ModbusProtocolReadDataFunctionCode.ReadCoilStatus,
AreaWidth = 0.125
}
},
{
"N",
new AreaOutputDef
{
Code = (int) ModbusProtocolReadDataFunctionCode.ReadCoilStatus,
AreaWidth = 0.125
}
},
{
"I",
new AreaOutputDef
{
Code = (int) ModbusProtocolReadDataFunctionCode.ReadInputStatus,
AreaWidth = 0.125
}
},
{
"S",
new AreaOutputDef
{
Code = (int) ModbusProtocolReadDataFunctionCode.ReadInputStatus,
AreaWidth = 0.125
}
},
{
"IW",
new AreaOutputDef {Code = (int) ModbusProtocolReadDataFunctionCode.ReadInputRegister, AreaWidth = 2}
},
{
"SW",
new AreaOutputDef {Code = (int) ModbusProtocolReadDataFunctionCode.ReadInputRegister, AreaWidth = 2}
},
{
"MW",
new AreaOutputDef {Code = (int) ModbusProtocolReadDataFunctionCode.ReadHoldRegister, AreaWidth = 2}
},
{
"NW",
new AreaOutputDef {Code = (int) ModbusProtocolReadDataFunctionCode.ReadHoldRegister, AreaWidth = 2}
},
{
"QW",
new AreaOutputDef {Code = (int) ModbusProtocolReadDataFunctionCode.ReadHoldRegister, AreaWidth = 2}
}
};
WriteFunctionCodeDictionary = new Dictionary<(string, bool), AreaOutputDef>
{
{
("Q", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiCoil,
AreaWidth = 0.125
}
},
{
("M", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiCoil,
AreaWidth = 0.125
}
},
{
("N", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiCoil,
AreaWidth = 0.125
}
},
{
("MW", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiRegister,
AreaWidth = 2
}
},
{
("NW", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiRegister,
AreaWidth = 2
}
},
{
("QW", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiRegister,
AreaWidth = 2
}
},
{
("Q", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleCoil,
AreaWidth = 0.125
}
},
{
("M", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleCoil,
AreaWidth = 0.125
}
},
{
("N", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleCoil,
AreaWidth = 0.125
}
},
{
("MW", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleRegister,
AreaWidth = 2
}
},
{
("NW", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleRegister,
AreaWidth = 2
}
},
{
("QW", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleRegister,
AreaWidth = 2
}
}
};
}
/// <summary>
/// 地址转换
/// </summary>
/// <param name="address">格式化的地址</param>
/// <param name="isRead">是否为读取,是为读取,否为写入</param>
/// <param name="isSingle">是否只写入一个数据</param>
/// <returns>翻译后的地址</returns>
public override AddressDef AddressTranslate(string address, bool isRead, bool isSingle)
{
address = address.ToUpper();
var splitString = address.Split(' ');
var head = splitString[0];
var tail = splitString[1];
string sub;
if (tail.Contains('.'))
{
var splitString2 = tail.Split('.');
sub = splitString2[1];
tail = splitString2[0];
}
else
{
sub = "0";
}
return isRead
? new AddressDef
{
AreaString = head,
Area = ReadFunctionCodeDictionary[head].Code,
Address = TransDictionary[head] + int.Parse(tail) - 1,
SubAddress = int.Parse(sub)
}
: new AddressDef
{
AreaString = head,
Area = WriteFunctionCodeDictionary[(head, isSingle)].Code,
Address = TransDictionary[head] + int.Parse(tail) - 1,
SubAddress = int.Parse(sub)
};
}
/// <summary>
/// 获取区域中的单个地址占用的字节长度
/// </summary>
/// <param name="area">区域名称</param>
/// <returns>字节长度</returns>
public override double GetAreaByteLength(string area)
{
return ReadFunctionCodeDictionary[area].AreaWidth;
}
}
}

View File

@@ -0,0 +1,13 @@
<Project Sdk="Microsoft.NET.Sdk">
<PropertyGroup>
<TargetFramework>net6.0</TargetFramework>
<ImplicitUsings>enable</ImplicitUsings>
<Nullable>enable</Nullable>
</PropertyGroup>
<ItemGroup>
<ProjectReference Include="..\Modbus.Net.Modbus\Modbus.Net.Modbus.csproj" />
</ItemGroup>
</Project>

View File

@@ -1,34 +1,5 @@
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
/// <summary>
/// 南大奥拓NA200H专用AddressFormater
/// </summary>
public class AddressFormaterNA200H : AddressFormater
{
/// <summary>
/// 格式化地址
/// </summary>
/// <param name="area">地址区域</param>
/// <param name="address">地址</param>
/// <returns>格式化的地址字符串</returns>
public override string FormatAddress(string area, int address)
{
return area + " " + address;
}
/// <summary>
/// 格式化地址
/// </summary>
/// <param name="area">地址区域</param>
/// <param name="address">地址</param>
/// <param name="subAddress">比特位地址</param>
/// <returns>格式化的地址字符串</returns>
public override string FormatAddress(string area, int address, int subAddress)
{
return area + " " + address + "." + subAddress;
}
}
/// <summary> /// <summary>
/// Modbus标准AddressFormater /// Modbus标准AddressFormater
/// </summary> /// </summary>

View File

@@ -1,5 +1,4 @@
using System.Collections.Generic; using System.Collections.Generic;
using System.Linq;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -29,260 +28,6 @@ namespace Modbus.Net.Modbus
} }
} }
/// <summary>
/// 南大奥拓NA200H数据单元翻译器
/// </summary>
public class AddressTranslatorNA200H : ModbusTranslatorBase
{
/// <summary>
/// 读功能码
/// </summary>
protected Dictionary<string, AreaOutputDef> ReadFunctionCodeDictionary;
/// <summary>
/// 功能码翻译至标准Modbus地址位置
/// </summary>
protected Dictionary<string, int> TransDictionary;
/// <summary>
/// 写功能码
/// </summary>
protected Dictionary<(string, bool), AreaOutputDef> WriteFunctionCodeDictionary;
/// <summary>
/// 构造器
/// </summary>
public AddressTranslatorNA200H()
{
TransDictionary = new Dictionary<string, int>
{
{"Q", 0},
{"M", 10000},
{"N", 30000},
{"I", 0},
{"S", 10000},
{"IW", 0},
{"SW", 5000},
{"MW", 0},
{"QW", 20000},
{"NW", 21000}
};
ReadFunctionCodeDictionary = new Dictionary<string, AreaOutputDef>
{
{
"Q",
new AreaOutputDef
{
Code = (int) ModbusProtocolReadDataFunctionCode.ReadCoilStatus,
AreaWidth = 0.125
}
},
{
"M",
new AreaOutputDef
{
Code = (int) ModbusProtocolReadDataFunctionCode.ReadCoilStatus,
AreaWidth = 0.125
}
},
{
"N",
new AreaOutputDef
{
Code = (int) ModbusProtocolReadDataFunctionCode.ReadCoilStatus,
AreaWidth = 0.125
}
},
{
"I",
new AreaOutputDef
{
Code = (int) ModbusProtocolReadDataFunctionCode.ReadInputStatus,
AreaWidth = 0.125
}
},
{
"S",
new AreaOutputDef
{
Code = (int) ModbusProtocolReadDataFunctionCode.ReadInputStatus,
AreaWidth = 0.125
}
},
{
"IW",
new AreaOutputDef {Code = (int) ModbusProtocolReadDataFunctionCode.ReadInputRegister, AreaWidth = 2}
},
{
"SW",
new AreaOutputDef {Code = (int) ModbusProtocolReadDataFunctionCode.ReadInputRegister, AreaWidth = 2}
},
{
"MW",
new AreaOutputDef {Code = (int) ModbusProtocolReadDataFunctionCode.ReadHoldRegister, AreaWidth = 2}
},
{
"NW",
new AreaOutputDef {Code = (int) ModbusProtocolReadDataFunctionCode.ReadHoldRegister, AreaWidth = 2}
},
{
"QW",
new AreaOutputDef {Code = (int) ModbusProtocolReadDataFunctionCode.ReadHoldRegister, AreaWidth = 2}
}
};
WriteFunctionCodeDictionary = new Dictionary<(string, bool), AreaOutputDef>
{
{
("Q", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiCoil,
AreaWidth = 0.125
}
},
{
("M", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiCoil,
AreaWidth = 0.125
}
},
{
("N", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiCoil,
AreaWidth = 0.125
}
},
{
("MW", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiRegister,
AreaWidth = 2
}
},
{
("NW", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiRegister,
AreaWidth = 2
}
},
{
("QW", false),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteMultiRegister,
AreaWidth = 2
}
},
{
("Q", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleCoil,
AreaWidth = 0.125
}
},
{
("M", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleCoil,
AreaWidth = 0.125
}
},
{
("N", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleCoil,
AreaWidth = 0.125
}
},
{
("MW", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleRegister,
AreaWidth = 2
}
},
{
("NW", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleRegister,
AreaWidth = 2
}
},
{
("QW", true),
new AreaOutputDef
{
Code = (int) ModbusProtocolWriteDataFunctionCode.WriteSingleRegister,
AreaWidth = 2
}
}
};
}
/// <summary>
/// 地址转换
/// </summary>
/// <param name="address">格式化的地址</param>
/// <param name="isRead">是否为读取,是为读取,否为写入</param>
/// <param name="isSingle">是否只写入一个数据</param>
/// <returns>翻译后的地址</returns>
public override AddressDef AddressTranslate(string address, bool isRead, bool isSingle)
{
address = address.ToUpper();
var splitString = address.Split(' ');
var head = splitString[0];
var tail = splitString[1];
string sub;
if (tail.Contains('.'))
{
var splitString2 = tail.Split('.');
sub = splitString2[1];
tail = splitString2[0];
}
else
{
sub = "0";
}
return isRead
? new AddressDef
{
AreaString = head,
Area = ReadFunctionCodeDictionary[head].Code,
Address = TransDictionary[head] + int.Parse(tail) - 1,
SubAddress = int.Parse(sub)
}
: new AddressDef
{
AreaString = head,
Area = WriteFunctionCodeDictionary[(head, isSingle)].Code,
Address = TransDictionary[head] + int.Parse(tail) - 1,
SubAddress = int.Parse(sub)
};
}
/// <summary>
/// 获取区域中的单个地址占用的字节长度
/// </summary>
/// <param name="area">区域名称</param>
/// <returns>字节长度</returns>
public override double GetAreaByteLength(string area)
{
return ReadFunctionCodeDictionary[area].AreaWidth;
}
}
/// <summary> /// <summary>
/// Modbus数据单元翻译器 /// Modbus数据单元翻译器
/// </summary> /// </summary>

View File

@@ -1,4 +1,4 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -13,7 +13,7 @@ namespace Modbus.Net.Modbus
/// <param name="slaveAddress">从站号</param> /// <param name="slaveAddress">从站号</param>
/// <param name="masterAddress">主站号</param> /// <param name="masterAddress">主站号</param>
public ModbusAsciiInTcpProtocol(byte slaveAddress, byte masterAddress) public ModbusAsciiInTcpProtocol(byte slaveAddress, byte masterAddress)
: this(ConfigurationManager.AppSettings["IP"], slaveAddress, masterAddress) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["IP"], slaveAddress, masterAddress)
{ {
} }

View File

@@ -1,4 +1,4 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
using System.Text; using System.Text;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
@@ -13,7 +13,7 @@ namespace Modbus.Net.Modbus
/// </summary> /// </summary>
/// <param name="ip">IP地址</param> /// <param name="ip">IP地址</param>
public ModbusAsciiInTcpProtocolLinker(string ip) public ModbusAsciiInTcpProtocolLinker(string ip)
: base(ip, int.Parse(ConfigurationManager.AppSettings["ModbusPort"] ?? "502"), false) : base(ip, int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["ModbusPort"] ?? "502"), false)
{ {
} }
@@ -25,7 +25,7 @@ namespace Modbus.Net.Modbus
public ModbusAsciiInTcpProtocolLinker(string ip, int port) public ModbusAsciiInTcpProtocolLinker(string ip, int port)
: base(ip, port) : base(ip, port)
{ {
((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(ConfigurationManager.AppSettings["FetchSleepTime"] ?? "100"))); ((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["FetchSleepTime"] ?? "100")));
} }
/// <summary> /// <summary>

View File

@@ -1,9 +1,4 @@
using System; using Microsoft.Extensions.Configuration;
using System.Collections.Generic;
using System.Configuration;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -18,7 +13,7 @@ namespace Modbus.Net.Modbus
/// <param name="slaveAddress">从站号</param> /// <param name="slaveAddress">从站号</param>
/// <param name="masterAddress">主站号</param> /// <param name="masterAddress">主站号</param>
public ModbusAsciiInUdpProtocol(byte slaveAddress, byte masterAddress) public ModbusAsciiInUdpProtocol(byte slaveAddress, byte masterAddress)
: this(ConfigurationManager.AppSettings["IP"], slaveAddress, masterAddress) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["IP"], slaveAddress, masterAddress)
{ {
} }

View File

@@ -1,9 +1,5 @@
using System; using Microsoft.Extensions.Configuration;
using System.Collections.Generic;
using System.Configuration;
using System.Linq;
using System.Text; using System.Text;
using System.Threading.Tasks;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -17,7 +13,7 @@ namespace Modbus.Net.Modbus
/// </summary> /// </summary>
/// <param name="ip">IP地址</param> /// <param name="ip">IP地址</param>
public ModbusAsciiInUdpProtocolLinker(string ip) public ModbusAsciiInUdpProtocolLinker(string ip)
: base(ip, int.Parse(ConfigurationManager.AppSettings["ModbusPort"] ?? "502"), false) : base(ip, int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["ModbusPort"] ?? "502"), false)
{ {
} }
@@ -29,7 +25,7 @@ namespace Modbus.Net.Modbus
public ModbusAsciiInUdpProtocolLinker(string ip, int port) public ModbusAsciiInUdpProtocolLinker(string ip, int port)
: base(ip, port) : base(ip, port)
{ {
((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(ConfigurationManager.AppSettings["FetchSleepTime"] ?? "0"))); ((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["FetchSleepTime"] ?? "0")));
} }
/// <summary> /// <summary>

View File

@@ -1,4 +1,4 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -13,7 +13,7 @@ namespace Modbus.Net.Modbus
/// <param name="slaveAddress">从站号</param> /// <param name="slaveAddress">从站号</param>
/// <param name="masterAddress">主站号</param> /// <param name="masterAddress">主站号</param>
public ModbusAsciiProtocol(byte slaveAddress, byte masterAddress) public ModbusAsciiProtocol(byte slaveAddress, byte masterAddress)
: this(ConfigurationManager.AppSettings["COM"], slaveAddress, masterAddress) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["COM"], slaveAddress, masterAddress)
{ {
} }

View File

@@ -1,5 +1,5 @@
using System.Collections.Generic; using Microsoft.Extensions.Configuration;
using System.Configuration; using System.Collections.Generic;
using System.IO.Ports; using System.IO.Ports;
using System.Text; using System.Text;
@@ -18,7 +18,7 @@ namespace Modbus.Net.Modbus
public ModbusAsciiProtocolLinker(string com, int slaveAddress) public ModbusAsciiProtocolLinker(string com, int slaveAddress)
: base(com, 9600, Parity.None, StopBits.One, 8, slaveAddress) : base(com, 9600, Parity.None, StopBits.One, 8, slaveAddress)
{ {
((BaseConnector)BaseConnector).AddController(new MatchController(new ICollection<(int,int)>[] { new List<(int,int)> { (1,1), (2,2) }, new List<(int, int)> { (3, 3), (4, 4) }}, int.Parse(ConfigurationManager.AppSettings["FetchSleepTime"] ?? "0"))); ((BaseConnector)BaseConnector).AddController(new MatchController(new ICollection<(int,int)>[] { new List<(int,int)> { (1,1), (2,2) }, new List<(int, int)> { (3, 3), (4, 4) }}, int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["FetchSleepTime"] ?? "0")));
} }
/// <summary> /// <summary>

View File

@@ -65,7 +65,7 @@ namespace Modbus.Net.Modbus
/// <summary> /// <summary>
/// 跟写数据有关的功能码 /// 跟写数据有关的功能码
/// </summary> /// </summary>
internal enum ModbusProtocolWriteDataFunctionCode : byte public enum ModbusProtocolWriteDataFunctionCode : byte
{ {
/// <summary> /// <summary>
/// 写单个线圈 /// 写单个线圈

View File

@@ -1,5 +1,4 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -14,7 +13,7 @@ namespace Modbus.Net.Modbus
/// <param name="slaveAddress">从站号</param> /// <param name="slaveAddress">从站号</param>
/// <param name="masterAddress">主站号</param> /// <param name="masterAddress">主站号</param>
public ModbusRtuInTcpProtocol(byte slaveAddress, byte masterAddress) public ModbusRtuInTcpProtocol(byte slaveAddress, byte masterAddress)
: this(ConfigurationManager.AppSettings["IP"], slaveAddress, masterAddress) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["IP"], slaveAddress, masterAddress)
{ {
} }

View File

@@ -1,4 +1,4 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -12,7 +12,7 @@ namespace Modbus.Net.Modbus
/// </summary> /// </summary>
/// <param name="ip">IP地址</param> /// <param name="ip">IP地址</param>
public ModbusRtuInTcpProtocolLinker(string ip) public ModbusRtuInTcpProtocolLinker(string ip)
: base(ip, int.Parse(ConfigurationManager.AppSettings["ModbusPort"] ?? "502"), false) : base(ip, int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["ModbusPort"] ?? "502"), false)
{ {
} }
@@ -24,7 +24,7 @@ namespace Modbus.Net.Modbus
public ModbusRtuInTcpProtocolLinker(string ip, int port) public ModbusRtuInTcpProtocolLinker(string ip, int port)
: base(ip, port) : base(ip, port)
{ {
((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(ConfigurationManager.AppSettings["FetchSleepTime"] ?? "0"))); ((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["FetchSleepTime"] ?? "0")));
} }
/// <summary> /// <summary>

View File

@@ -1,9 +1,4 @@
using System; using Microsoft.Extensions.Configuration;
using System.Collections.Generic;
using System.Configuration;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -18,7 +13,7 @@ namespace Modbus.Net.Modbus
/// <param name="slaveAddress">从站号</param> /// <param name="slaveAddress">从站号</param>
/// <param name="masterAddress">主站号</param> /// <param name="masterAddress">主站号</param>
public ModbusRtuInUdpProtocol(byte slaveAddress, byte masterAddress) public ModbusRtuInUdpProtocol(byte slaveAddress, byte masterAddress)
: this(ConfigurationManager.AppSettings["IP"], slaveAddress, masterAddress) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["IP"], slaveAddress, masterAddress)
{ {
} }

View File

@@ -1,9 +1,4 @@
using System; using Microsoft.Extensions.Configuration;
using System.Collections.Generic;
using System.Configuration;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -17,7 +12,7 @@ namespace Modbus.Net.Modbus
/// </summary> /// </summary>
/// <param name="ip">IP地址</param> /// <param name="ip">IP地址</param>
public ModbusRtuInUdpProtocolLinker(string ip) public ModbusRtuInUdpProtocolLinker(string ip)
: base(ip, int.Parse(ConfigurationManager.AppSettings["ModbusPort"] ?? "502"), false) : base(ip, int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["ModbusPort"] ?? "502"), false)
{ {
} }
@@ -29,7 +24,7 @@ namespace Modbus.Net.Modbus
public ModbusRtuInUdpProtocolLinker(string ip, int port) public ModbusRtuInUdpProtocolLinker(string ip, int port)
: base(ip, port) : base(ip, port)
{ {
((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(ConfigurationManager.AppSettings["FetchSleepTime"] ?? "0"))); ((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["FetchSleepTime"] ?? "0")));
} }
/// <summary> /// <summary>

View File

@@ -1,4 +1,4 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -13,7 +13,7 @@ namespace Modbus.Net.Modbus
/// <param name="slaveAddress">从站号</param> /// <param name="slaveAddress">从站号</param>
/// <param name="masterAddress">主站号</param> /// <param name="masterAddress">主站号</param>
public ModbusRtuProtocol(byte slaveAddress, byte masterAddress) public ModbusRtuProtocol(byte slaveAddress, byte masterAddress)
: this(ConfigurationManager.AppSettings["COM"], slaveAddress, masterAddress) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["COM"], slaveAddress, masterAddress)
{ {
} }

View File

@@ -1,5 +1,5 @@
using System.Collections.Generic; using Microsoft.Extensions.Configuration;
using System.Configuration; using System.Collections.Generic;
using System.IO.Ports; using System.IO.Ports;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
@@ -17,7 +17,7 @@ namespace Modbus.Net.Modbus
public ModbusRtuProtocolLinker(string com, int slaveAddress) public ModbusRtuProtocolLinker(string com, int slaveAddress)
: base(com, 9600, Parity.None, StopBits.One, 8, slaveAddress) : base(com, 9600, Parity.None, StopBits.One, 8, slaveAddress)
{ {
((BaseConnector)BaseConnector).AddController(new MatchController(new ICollection<(int,int)>[]{new List<(int,int)>{(0,0)}, new List<(int, int)>{(1,1)}}, int.Parse(ConfigurationManager.AppSettings["FetchSleepTime"] ?? "0"))); ((BaseConnector)BaseConnector).AddController(new MatchController(new ICollection<(int,int)>[]{new List<(int,int)>{(0,0)}, new List<(int, int)>{(1,1)}}, int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["FetchSleepTime"] ?? "0")));
} }
/// <summary> /// <summary>

View File

@@ -1,4 +1,4 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -13,7 +13,7 @@ namespace Modbus.Net.Modbus
/// <param name="slaveAddress">从站号</param> /// <param name="slaveAddress">从站号</param>
/// <param name="masterAddress">主站号</param> /// <param name="masterAddress">主站号</param>
public ModbusTcpProtocol(byte slaveAddress, byte masterAddress) public ModbusTcpProtocol(byte slaveAddress, byte masterAddress)
: this(ConfigurationManager.AppSettings["IP"], slaveAddress, masterAddress) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["IP"], slaveAddress, masterAddress)
{ {
} }

View File

@@ -1,5 +1,5 @@
using System.Collections.Generic; using Microsoft.Extensions.Configuration;
using System.Configuration; using System.Collections.Generic;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -13,7 +13,7 @@ namespace Modbus.Net.Modbus
/// </summary> /// </summary>
/// <param name="ip">IP地址</param> /// <param name="ip">IP地址</param>
public ModbusTcpProtocolLinker(string ip) public ModbusTcpProtocolLinker(string ip)
: this(ip, int.Parse(ConfigurationManager.AppSettings["ModbusPort"] ?? "502")) : this(ip, int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["ModbusPort"] ?? "502"))
{ {
} }
@@ -24,7 +24,7 @@ namespace Modbus.Net.Modbus
/// <param name="port">端口</param> /// <param name="port">端口</param>
public ModbusTcpProtocolLinker(string ip, int port) : base(ip, port) public ModbusTcpProtocolLinker(string ip, int port) : base(ip, port)
{ {
((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(ConfigurationManager.AppSettings["FetchSleepTime"] ?? "0"), true, DuplicateWithCount.GetDuplcateFunc(new List<int>{4,5}, 6))); ((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["FetchSleepTime"] ?? "0"), true, DuplicateWithCount.GetDuplcateFunc(new List<int>{4,5}, 6)));
} }
/// <summary> /// <summary>

View File

@@ -1,4 +1,4 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -13,7 +13,7 @@ namespace Modbus.Net.Modbus
/// <param name="slaveAddress">从站号</param> /// <param name="slaveAddress">从站号</param>
/// <param name="masterAddress">主站号</param> /// <param name="masterAddress">主站号</param>
public ModbusUdpProtocol(byte slaveAddress, byte masterAddress) public ModbusUdpProtocol(byte slaveAddress, byte masterAddress)
: this(ConfigurationManager.AppSettings["IP"], slaveAddress, masterAddress) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["IP"], slaveAddress, masterAddress)
{ {
} }

View File

@@ -1,5 +1,5 @@
using System.Collections.Generic; using Microsoft.Extensions.Configuration;
using System.Configuration; using System.Collections.Generic;
namespace Modbus.Net.Modbus namespace Modbus.Net.Modbus
{ {
@@ -13,7 +13,7 @@ namespace Modbus.Net.Modbus
/// </summary> /// </summary>
/// <param name="ip">IP地址</param> /// <param name="ip">IP地址</param>
public ModbusUdpProtocolLinker(string ip) public ModbusUdpProtocolLinker(string ip)
: this(ip, int.Parse(ConfigurationManager.AppSettings["ModbusPort"] ?? "502")) : this(ip, int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["ModbusPort"] ?? "502"))
{ {
} }
@@ -24,7 +24,7 @@ namespace Modbus.Net.Modbus
/// <param name="port">端口</param> /// <param name="port">端口</param>
public ModbusUdpProtocolLinker(string ip, int port) : base(ip, port) public ModbusUdpProtocolLinker(string ip, int port) : base(ip, port)
{ {
((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(ConfigurationManager.AppSettings["FetchSleepTime"] ?? "0"), true, DuplicateWithCount.GetDuplcateFunc(new List<int> { 4, 5 }, 6))); ((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["FetchSleepTime"] ?? "0"), true, DuplicateWithCount.GetDuplcateFunc(new List<int> { 4, 5 }, 6)));
} }
/// <summary> /// <summary>

View File

@@ -1,5 +1,5 @@
using System.Configuration; using System.Threading.Tasks;
using System.Threading.Tasks; using Microsoft.Extensions.Configuration;
using Nito.AsyncEx; using Nito.AsyncEx;
namespace Modbus.Net.Siemens namespace Modbus.Net.Siemens
@@ -18,7 +18,7 @@ namespace Modbus.Net.Siemens
/// <param name="slaveAddress">从站号</param> /// <param name="slaveAddress">从站号</param>
/// <param name="masterAddress">主站号</param> /// <param name="masterAddress">主站号</param>
public SiemensPpiProtocol(byte slaveAddress, byte masterAddress) public SiemensPpiProtocol(byte slaveAddress, byte masterAddress)
: this(ConfigurationManager.AppSettings["COM"], slaveAddress, masterAddress) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["COM"], slaveAddress, masterAddress)
{ {
} }

View File

@@ -1,4 +1,4 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
using System.IO.Ports; using System.IO.Ports;
using System.Threading; using System.Threading;
using System.Threading.Tasks; using System.Threading.Tasks;
@@ -19,7 +19,7 @@ namespace Modbus.Net.Siemens
public SiemensPpiProtocolLinker(string com, int slaveAddress) public SiemensPpiProtocolLinker(string com, int slaveAddress)
: base(com, 9600, Parity.Even, StopBits.One, 8, slaveAddress) : base(com, 9600, Parity.Even, StopBits.One, 8, slaveAddress)
{ {
((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(ConfigurationManager.AppSettings["FetchSleepTime"] ?? "0"))); ((BaseConnector)BaseConnector).AddController(new FifoController(int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["FetchSleepTime"] ?? "0")));
} }
/// <summary> /// <summary>

View File

@@ -1,5 +1,5 @@
using System.Configuration; using System.Threading.Tasks;
using System.Threading.Tasks; using Microsoft.Extensions.Configuration;
using Nito.AsyncEx; using Nito.AsyncEx;
namespace Modbus.Net.Siemens namespace Modbus.Net.Siemens
@@ -31,7 +31,7 @@ namespace Modbus.Net.Siemens
/// <param name="maxPdu"></param> /// <param name="maxPdu"></param>
public SiemensTcpProtocol(byte tdpuSize, ushort tsapSrc, ushort tsapDst, ushort maxCalling, ushort maxCalled, public SiemensTcpProtocol(byte tdpuSize, ushort tsapSrc, ushort tsapDst, ushort maxCalling, ushort maxCalled,
ushort maxPdu) ushort maxPdu)
: this(tdpuSize, tsapSrc, tsapDst, maxCalling, maxCalled, maxPdu, ConfigurationManager.AppSettings["IP"]) : this(tdpuSize, tsapSrc, tsapDst, maxCalling, maxCalled, maxPdu, new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["IP"])
{ {
} }
@@ -49,7 +49,7 @@ namespace Modbus.Net.Siemens
ushort maxPdu, string ip) ushort maxPdu, string ip)
: this( : this(
tdpuSize, tsapSrc, tsapDst, maxCalling, maxCalled, maxPdu, ip, tdpuSize, tsapSrc, tsapDst, maxCalling, maxCalled, maxPdu, ip,
int.Parse(ConfigurationManager.AppSettings["SiemensPort"] ?? "102")) int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["SiemensPort"] ?? "102"))
{ {
} }

View File

@@ -1,7 +1,6 @@
using System; using Microsoft.Extensions.Configuration;
using System;
using System.Collections.Generic; using System.Collections.Generic;
using System.Configuration;
using System.Linq;
namespace Modbus.Net.Siemens namespace Modbus.Net.Siemens
{ {
@@ -15,7 +14,7 @@ namespace Modbus.Net.Siemens
/// </summary> /// </summary>
/// <param name="ip">IP地址</param> /// <param name="ip">IP地址</param>
public SiemensTcpProtocolLinker(string ip) public SiemensTcpProtocolLinker(string ip)
: this(ip, int.Parse(ConfigurationManager.AppSettings["SiemensPort"] ?? "102")) : this(ip, int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["SiemensPort"] ?? "102"))
{ {
} }
@@ -27,7 +26,7 @@ namespace Modbus.Net.Siemens
public SiemensTcpProtocolLinker(string ip, int port) public SiemensTcpProtocolLinker(string ip, int port)
: base(ip, port) : base(ip, port)
{ {
((BaseConnector)BaseConnector).AddController(new MatchDirectlySendController(new ICollection<(int,int)>[] { new List<(int,int)> { (11,11), (12,12) } }, int.Parse(ConfigurationManager.AppSettings["FetchSleepTime"] ?? "0"), DuplicateWithCount.GetDuplcateFunc(new List<int>{2, 3}, 0))); ((BaseConnector)BaseConnector).AddController(new MatchDirectlySendController(new ICollection<(int,int)>[] { new List<(int,int)> { (11,11), (12,12) } }, DuplicateWithCount.GetDuplcateFunc(new List<int>{2, 3}, 0)));
} }
/// <summary> /// <summary>

View File

@@ -22,6 +22,8 @@ Project("{2150E333-8FDC-42A3-9474-1A3956D46DE8}") = "Samples", "Samples", "{3597
EndProject EndProject
Project("{9A19103F-16F7-4668-BE54-9A1E7A4F7556}") = "Modbus.Net.Modbus.Test", "..\Samples\Modbus.Net.Modbus.Test\Modbus.Net.Modbus.Test.csproj", "{22A35CA8-CDCF-416D-BA84-08C933B4A3DE}" Project("{9A19103F-16F7-4668-BE54-9A1E7A4F7556}") = "Modbus.Net.Modbus.Test", "..\Samples\Modbus.Net.Modbus.Test\Modbus.Net.Modbus.Test.csproj", "{22A35CA8-CDCF-416D-BA84-08C933B4A3DE}"
EndProject EndProject
Project("{FAE04EC0-301F-11D3-BF4B-00C04F79EFBC}") = "Modbus.Net.Modbus.NA200H", "Modbus.Net.Modbus.NA200H\Modbus.Net.Modbus.NA200H.csproj", "{D4AF0E1E-676E-43B6-BAA3-BFC329D68C80}"
EndProject
Global Global
GlobalSection(SolutionConfigurationPlatforms) = preSolution GlobalSection(SolutionConfigurationPlatforms) = preSolution
Debug|Any CPU = Debug|Any CPU Debug|Any CPU = Debug|Any CPU
@@ -48,6 +50,10 @@ Global
{22A35CA8-CDCF-416D-BA84-08C933B4A3DE}.Debug|Any CPU.Build.0 = Debug|Any CPU {22A35CA8-CDCF-416D-BA84-08C933B4A3DE}.Debug|Any CPU.Build.0 = Debug|Any CPU
{22A35CA8-CDCF-416D-BA84-08C933B4A3DE}.Release|Any CPU.ActiveCfg = Release|Any CPU {22A35CA8-CDCF-416D-BA84-08C933B4A3DE}.Release|Any CPU.ActiveCfg = Release|Any CPU
{22A35CA8-CDCF-416D-BA84-08C933B4A3DE}.Release|Any CPU.Build.0 = Release|Any CPU {22A35CA8-CDCF-416D-BA84-08C933B4A3DE}.Release|Any CPU.Build.0 = Release|Any CPU
{D4AF0E1E-676E-43B6-BAA3-BFC329D68C80}.Debug|Any CPU.ActiveCfg = Debug|Any CPU
{D4AF0E1E-676E-43B6-BAA3-BFC329D68C80}.Debug|Any CPU.Build.0 = Debug|Any CPU
{D4AF0E1E-676E-43B6-BAA3-BFC329D68C80}.Release|Any CPU.ActiveCfg = Release|Any CPU
{D4AF0E1E-676E-43B6-BAA3-BFC329D68C80}.Release|Any CPU.Build.0 = Release|Any CPU
EndGlobalSection EndGlobalSection
GlobalSection(SolutionProperties) = preSolution GlobalSection(SolutionProperties) = preSolution
HideSolutionNode = FALSE HideSolutionNode = FALSE

View File

@@ -1,16 +0,0 @@
<?xml version="1.0" encoding="utf-8"?>
<configuration>
<appSettings>
<add key="COM" value="COM1" />
<add key="FBoxOpcDaHost" value="opcda://localhost/FBoxOpcServer" />
<add key="IP" value="192.168.1.1" />
<add key="ComConnectionTimeout" value="3000" />
<add key="IPConnectionTimeout" value="5000" />
<add key="ModbusPort" value="502" />
<add key="OpcDaHost" value="opcda://localhost/..." />
<add key="OpcUaHost" value="opc.tcp://localhost/..." />
<add key="SiemensPort" value="102" />
<add key="FetchSleepTime" value="100" />
</appSettings>
</configuration>

View File

@@ -1,5 +1,4 @@
using System; using System;
using System.Threading;
using System.Threading.Tasks; using System.Threading.Tasks;
using Nito.AsyncEx; using Nito.AsyncEx;
using Serilog; using Serilog;

View File

@@ -1,10 +1,4 @@
using System; namespace Modbus.Net
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace Modbus.Net
{ {
/// <summary> /// <summary>
/// 数据返回代理参数 /// 数据返回代理参数

View File

@@ -1,8 +1,5 @@
using System; using System;
using System.Collections.Generic; using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace Modbus.Net namespace Modbus.Net
{ {
@@ -16,6 +13,8 @@ namespace Modbus.Net
/// </summary> /// </summary>
/// <param name="receiveMessage">收到的报文信息</param> /// <param name="receiveMessage">收到的报文信息</param>
/// <param name="packageCountPositions">收到的断包长度查询位置</param> /// <param name="packageCountPositions">收到的断包长度查询位置</param>
/// <param name="otherCount">除掉长度查询信息外其它报文的长度
/// 注意该长度不包含CRC校验</param>
/// <returns>切分后的报文信息</returns> /// <returns>切分后的报文信息</returns>
private static ICollection<byte[]> DuplicateMessages(byte[] receiveMessage, ICollection<int> packageCountPositions, int otherCount) private static ICollection<byte[]> DuplicateMessages(byte[] receiveMessage, ICollection<int> packageCountPositions, int otherCount)
{ {
@@ -52,6 +51,8 @@ namespace Modbus.Net
/// 获取按照长度断包的函数 /// 获取按照长度断包的函数
/// </summary> /// </summary>
/// <param name="packageCountPositions">断包长度的位置信息</param> /// <param name="packageCountPositions">断包长度的位置信息</param>
/// <param name="otherCount">除掉长度查询信息外其它报文的长度
/// 注意该长度不包含CRC校验</param>
/// <returns>断包函数</returns> /// <returns>断包函数</returns>
public static Func<byte[], ICollection<byte[]>> GetDuplcateFunc(ICollection<int> packageCountPositions, int otherCount) public static Func<byte[], ICollection<byte[]>> GetDuplcateFunc(ICollection<int> packageCountPositions, int otherCount)
{ {

View File

@@ -1,8 +1,5 @@
using System; using System;
using System.Collections.Generic; using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace Modbus.Net namespace Modbus.Net
{ {
@@ -12,9 +9,9 @@ namespace Modbus.Net
public class MatchDirectlySendController : MatchController public class MatchDirectlySendController : MatchController
{ {
/// <inheritdoc /> /// <inheritdoc />
public MatchDirectlySendController(ICollection<(int, int)>[] keyMatches, int acquireTime, public MatchDirectlySendController(ICollection<(int, int)>[] keyMatches,
Func<byte[], ICollection<byte[]>> duplicateFunc = null) : base(keyMatches, Func<byte[], ICollection<byte[]>> duplicateFunc = null) : base(keyMatches,
acquireTime, false, duplicateFunc) 0, false, duplicateFunc)
{ {
} }

View File

@@ -1,10 +1,6 @@
using System; using System;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace Modbus.Net.Interface namespace Modbus.Net
{ {
public interface IMachine : IMachine<string> public interface IMachine : IMachine<string>
{ {

View File

@@ -1,7 +1,7 @@
using System; using System;
using System.Threading.Tasks; using System.Threading.Tasks;
namespace Modbus.Net.Interface namespace Modbus.Net
{ {
/// <summary> /// <summary>
/// 没有Id的设备属性 /// 没有Id的设备属性

View File

@@ -1,10 +1,4 @@
using System; namespace Modbus.Net
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace Modbus.Net.Interface
{ {
public interface IUtility : IUtilityProperty, IUtilityMethodData public interface IUtility : IUtilityProperty, IUtilityMethodData
{ {

View File

@@ -1,10 +1,6 @@
using System; using System.Threading.Tasks;
using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
namespace Modbus.Net.Interface namespace Modbus.Net
{ {
/// <summary> /// <summary>
/// Api入口的抽象 /// Api入口的抽象

View File

@@ -1,14 +1,11 @@
using Quartz.Listener; using Quartz.Listener;
using Quartz; using Quartz;
using Serilog; using Serilog;
using System;
using System.Collections.Generic; using System.Collections.Generic;
using System.Linq;
using System.Text;
using System.Threading; using System.Threading;
using System.Threading.Tasks; using System.Threading.Tasks;
namespace Modbus.Net.Job namespace Modbus.Net
{ {
public class JobChainingJobListenerWithDataMap : JobListenerSupport public class JobChainingJobListenerWithDataMap : JobListenerSupport
{ {
@@ -31,7 +28,7 @@ namespace Modbus.Net.Job
/// </summary> /// </summary>
/// <param name="firstJob">a JobKey with the name and group of the first job</param> /// <param name="firstJob">a JobKey with the name and group of the first job</param>
/// <param name="secondJob">a JobKey with the name and group of the follow-up job</param> /// <param name="secondJob">a JobKey with the name and group of the follow-up job</param>
public new void AddJobChainLink(JobKey firstJob, JobKey secondJob) public void AddJobChainLink(JobKey firstJob, JobKey secondJob)
{ {
chainLinks.Add(firstJob, secondJob); chainLinks.Add(firstJob, secondJob);
} }

View File

@@ -1,29 +1,28 @@
using Modbus.Net.Interface; using Quartz;
using Quartz;
using Quartz.Impl; using Quartz.Impl;
using Quartz.Impl.Matchers; using Quartz.Impl.Matchers;
using System; using System;
using System.Collections.Generic; using System.Collections.Generic;
using System.Threading.Tasks; using System.Threading.Tasks;
namespace Modbus.Net.Job namespace Modbus.Net
{ {
public sealed class MachineJobSchedulerCreator public sealed class MachineJobSchedulerCreator
{ {
public static async Task<MachineGetJobScheduler> CreateScheduler(int count, int interval) public static async Task<MachineGetJobScheduler> CreateScheduler(string triggerKey, int count, int interval)
{ {
IScheduler scheduler = await StdSchedulerFactory.GetDefaultScheduler(); IScheduler scheduler = await StdSchedulerFactory.GetDefaultScheduler();
ITrigger trigger; ITrigger trigger;
if (count >= 0) if (count >= 0)
trigger = TriggerBuilder.Create() trigger = TriggerBuilder.Create()
.WithIdentity("Modbus.Net.DataQuery.Trigger", "Modbus.Net.DataQuery.Group") .WithIdentity("Modbus.Net.DataQuery.Trigger."+ triggerKey, "Modbus.Net.DataQuery.Group")
.StartNow() .StartNow()
.WithSimpleSchedule(b => b.WithIntervalInSeconds(interval).WithRepeatCount(count)) .WithSimpleSchedule(b => b.WithIntervalInSeconds(interval).WithRepeatCount(count))
.Build(); .Build();
else else
trigger = TriggerBuilder.Create() trigger = TriggerBuilder.Create()
.WithIdentity("Modbus.Net.DataQuery.Trigger", "Modbus.Net.DataQuery.Group") .WithIdentity("Modbus.Net.DataQuery.Trigger."+ triggerKey, "Modbus.Net.DataQuery.Group")
.StartNow() .StartNow()
.WithSimpleSchedule(b => b.WithIntervalInSeconds(interval).RepeatForever()) .WithSimpleSchedule(b => b.WithIntervalInSeconds(interval).RepeatForever())
.Build(); .Build();
@@ -59,6 +58,26 @@ namespace Modbus.Net.Job
return new MachineQueryJobScheduler(_scheduler, _trigger, jobKey); return new MachineQueryJobScheduler(_scheduler, _trigger, jobKey);
} }
public async Task<MachineSetJobScheduler> To(string queryId, Dictionary<string, ReturnUnit> values, IMachineMethodData machine, MachineDataType machineDataType)
{
JobKey jobKey = JobKey.Create("Modbus.Net.DataQuery.Job." + queryId, "Modbus.Net.DataQuery.Group");
IJobDetail job = JobBuilder.Create<MachineSetDataJob>()
.WithIdentity(jobKey)
.Build();
job.JobDataMap.Put("DataType", machineDataType);
job.JobDataMap.Put("Machine", machine);
job.JobDataMap.Put("Value", values);
await _scheduler.ScheduleJob(job, _trigger);
JobChainingJobListenerWithDataMap listener = new JobChainingJobListenerWithDataMap("Modbus.Net.DataQuery.Chain", false);
_scheduler.ListenerManager.AddJobListener(listener, GroupMatcher<JobKey>.GroupEquals("Modbus.Net.DataQuery.Group"));
return new MachineSetJobScheduler(_scheduler, _trigger, listener, jobKey);
}
} }
public class MachineQueryJobScheduler public class MachineQueryJobScheduler

View File

@@ -1,4 +1,4 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
using System.IO.Ports; using System.IO.Ports;
namespace Modbus.Net namespace Modbus.Net
@@ -17,7 +17,7 @@ namespace Modbus.Net
/// <param name="dataBits">数据位</param> /// <param name="dataBits">数据位</param>
/// <param name="slaveAddress">从站地址</param> /// <param name="slaveAddress">从站地址</param>
protected ComProtocolLinker(int baudRate, Parity parity, StopBits stopBits, int dataBits, int slaveAddress) protected ComProtocolLinker(int baudRate, Parity parity, StopBits stopBits, int dataBits, int slaveAddress)
: this(ConfigurationManager.AppSettings["COM"], baudRate, parity, stopBits, dataBits, slaveAddress) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["COM"], baudRate, parity, stopBits, dataBits, slaveAddress)
{ {
} }
@@ -35,7 +35,7 @@ namespace Modbus.Net
int slaveAddress, bool isFullDuplex = false) int slaveAddress, bool isFullDuplex = false)
: this( : this(
com, baudRate, parity, stopBits, dataBits, com, baudRate, parity, stopBits, dataBits,
int.Parse(ConfigurationManager.AppSettings["ComConnectionTimeout"] ?? "-1"), slaveAddress, isFullDuplex) int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["ComConnectionTimeout"] ?? "-1"), slaveAddress, isFullDuplex)
{ {
} }

View File

@@ -1,4 +1,5 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
namespace Modbus.Net namespace Modbus.Net
{ {
@@ -11,7 +12,7 @@ namespace Modbus.Net
/// 构造器 /// 构造器
/// </summary> /// </summary>
protected TcpProtocolLinker(int port) protected TcpProtocolLinker(int port)
: this(ConfigurationManager.AppSettings["IP"], port) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["IP"], port)
{ {
} }
@@ -22,7 +23,7 @@ namespace Modbus.Net
/// <param name="port">端口</param> /// <param name="port">端口</param>
/// <param name="isFullDuplex">是否为全双工</param> /// <param name="isFullDuplex">是否为全双工</param>
protected TcpProtocolLinker(string ip, int port, bool isFullDuplex = true) protected TcpProtocolLinker(string ip, int port, bool isFullDuplex = true)
: this(ip, port, int.Parse(ConfigurationManager.AppSettings["IPConnectionTimeout"] ?? "-1"), isFullDuplex) : this(ip, port, int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["IPConnectionTimeout"] ?? "-1"), isFullDuplex)
{ {
} }

View File

@@ -1,4 +1,5 @@
using System.Configuration; using Microsoft.Extensions.Configuration;
namespace Modbus.Net namespace Modbus.Net
{ {
@@ -11,7 +12,7 @@ namespace Modbus.Net
/// 构造器 /// 构造器
/// </summary> /// </summary>
protected UdpProtocolLinker(int port) protected UdpProtocolLinker(int port)
: this(ConfigurationManager.AppSettings["IP"], port) : this(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["IP"], port)
{ {
} }
@@ -22,7 +23,7 @@ namespace Modbus.Net
/// <param name="port">端口</param> /// <param name="port">端口</param>
/// <param name="isFullDuplex">是否为全双工</param> /// <param name="isFullDuplex">是否为全双工</param>
protected UdpProtocolLinker(string ip, int port, bool isFullDuplex = true) protected UdpProtocolLinker(string ip, int port, bool isFullDuplex = true)
: this(ip, port, int.Parse(ConfigurationManager.AppSettings["IPConnectionTimeout"] ?? "-1"), isFullDuplex) : this(ip, port, int.Parse(new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetSection("Config")["IPConnectionTimeout"] ?? "-1"), isFullDuplex)
{ {
} }

View File

@@ -2,7 +2,6 @@
using System.Collections.Generic; using System.Collections.Generic;
using System.Linq; using System.Linq;
using System.Threading.Tasks; using System.Threading.Tasks;
using Modbus.Net.Interface;
using Serilog; using Serilog;
namespace Modbus.Net namespace Modbus.Net

View File

@@ -27,11 +27,11 @@
</PropertyGroup> </PropertyGroup>
<ItemGroup> <ItemGroup>
<PackageReference Include="Microsoft.Extensions.Configuration.Json" Version="7.0.0" />
<PackageReference Include="Microsoft.Extensions.Logging.Abstractions" Version="7.0.0" /> <PackageReference Include="Microsoft.Extensions.Logging.Abstractions" Version="7.0.0" />
<PackageReference Include="Nito.AsyncEx" Version="5.1.2" /> <PackageReference Include="Nito.AsyncEx" Version="5.1.2" />
<PackageReference Include="Quartz" Version="3.6.0" /> <PackageReference Include="Quartz" Version="3.6.0" />
<PackageReference Include="Serilog" Version="2.12.0" /> <PackageReference Include="Serilog" Version="2.12.0" />
<PackageReference Include="System.Configuration.ConfigurationManager" Version="7.0.0" />
<PackageReference Include="System.IO.Ports" Version="7.0.0" /> <PackageReference Include="System.IO.Ports" Version="7.0.0" />
<PackageReference Include="System.ValueTuple" Version="4.5.0" /> <PackageReference Include="System.ValueTuple" Version="4.5.0" />
</ItemGroup> </ItemGroup>

View File

@@ -1,6 +1,5 @@
using System; using System;
using System.Collections.Generic; using System.Collections.Generic;
using System.Linq;
using System.Reflection; using System.Reflection;
using System.Threading.Tasks; using System.Threading.Tasks;

View File

@@ -3,7 +3,6 @@ using System.Collections.Generic;
using System.Linq; using System.Linq;
using System.Threading.Tasks; using System.Threading.Tasks;
using Serilog; using Serilog;
using Modbus.Net.Interface;
/// <summary> /// <summary>
/// 端格式 /// 端格式

View File

@@ -0,0 +1,11 @@
{
"Config": {
"COM": "COM1",
"IP": "192.168.1.1",
"ComConnectionTimeout": "3000",
"IPConnectionTimeout": "5000",
"ModbusPort": "502",
"SiemensPort": "102",
"FetchSleepTime": "100"
}
}

View File

@@ -0,0 +1,36 @@
using Microsoft.EntityFrameworkCore;
using Microsoft.Extensions.Configuration;
using System.ComponentModel.DataAnnotations;
namespace Modbus.Net.Modbus.Test
{
public class DatabaseWriteContext : DbContext
{
static readonly string connectionString = new ConfigurationBuilder().AddJsonFile($"appsettings.json").Build().GetConnectionString("DatabaseWriteConnectionString")!;
public DbSet<DatabaseWriteEntity> DatabaseWrites { get; set; }
protected override void OnConfiguring(DbContextOptionsBuilder optionsBuilder)
{
optionsBuilder.UseMySql(connectionString, ServerVersion.AutoDetect(connectionString));
}
}
public class DatabaseWriteEntity
{
[Key]
public int Id { get; set; }
public double? Value1 { get; set; }
public double? Value2 { get; set; }
public double? Value3 { get; set; }
public double? Value4 { get; set; }
public double? Value5 { get; set; }
public double? Value6 { get; set; }
public double? Value7 { get; set; }
public double? Value8 { get; set; }
public double? Value9 { get; set; }
public double? Value10 { get; set; }
public DateTime UpdateTime { get; set; }
}
}

View File

@@ -0,0 +1,71 @@
// <auto-generated />
using System;
using Microsoft.EntityFrameworkCore;
using Microsoft.EntityFrameworkCore.Infrastructure;
using Microsoft.EntityFrameworkCore.Migrations;
using Microsoft.EntityFrameworkCore.Storage.ValueConversion;
using Modbus.Net.Modbus.Test;
#nullable disable
namespace Modbus.Net.Modbus.Test.Migrations
{
[DbContext(typeof(DatabaseWriteContext))]
[Migration("20230212103438_InitialCreate")]
partial class InitialCreate
{
/// <inheritdoc />
protected override void BuildTargetModel(ModelBuilder modelBuilder)
{
#pragma warning disable 612, 618
modelBuilder
.HasAnnotation("ProductVersion", "7.0.2")
.HasAnnotation("Relational:MaxIdentifierLength", 64);
modelBuilder.Entity("Modbus.Net.Modbus.Test.DatabaseWriteEntity", b =>
{
b.Property<int>("Id")
.ValueGeneratedOnAdd()
.HasColumnType("int");
b.Property<DateTime>("UpdateTime")
.HasColumnType("datetime(6)");
b.Property<double?>("Value1")
.HasColumnType("double");
b.Property<double?>("Value10")
.HasColumnType("double");
b.Property<double?>("Value2")
.HasColumnType("double");
b.Property<double?>("Value3")
.HasColumnType("double");
b.Property<double?>("Value4")
.HasColumnType("double");
b.Property<double?>("Value5")
.HasColumnType("double");
b.Property<double?>("Value6")
.HasColumnType("double");
b.Property<double?>("Value7")
.HasColumnType("double");
b.Property<double?>("Value8")
.HasColumnType("double");
b.Property<double?>("Value9")
.HasColumnType("double");
b.HasKey("Id");
b.ToTable("DatabaseWrites");
});
#pragma warning restore 612, 618
}
}
}

View File

@@ -0,0 +1,50 @@
using System;
using Microsoft.EntityFrameworkCore.Metadata;
using Microsoft.EntityFrameworkCore.Migrations;
#nullable disable
namespace Modbus.Net.Modbus.Test.Migrations
{
/// <inheritdoc />
public partial class InitialCreate : Migration
{
/// <inheritdoc />
protected override void Up(MigrationBuilder migrationBuilder)
{
migrationBuilder.AlterDatabase()
.Annotation("MySql:CharSet", "utf8mb4");
migrationBuilder.CreateTable(
name: "DatabaseWrites",
columns: table => new
{
Id = table.Column<int>(type: "int", nullable: false)
.Annotation("MySql:ValueGenerationStrategy", MySqlValueGenerationStrategy.IdentityColumn),
Value1 = table.Column<double>(type: "double", nullable: true),
Value2 = table.Column<double>(type: "double", nullable: true),
Value3 = table.Column<double>(type: "double", nullable: true),
Value4 = table.Column<double>(type: "double", nullable: true),
Value5 = table.Column<double>(type: "double", nullable: true),
Value6 = table.Column<double>(type: "double", nullable: true),
Value7 = table.Column<double>(type: "double", nullable: true),
Value8 = table.Column<double>(type: "double", nullable: true),
Value9 = table.Column<double>(type: "double", nullable: true),
Value10 = table.Column<double>(type: "double", nullable: true),
UpdateTime = table.Column<DateTime>(type: "datetime(6)", nullable: false)
},
constraints: table =>
{
table.PrimaryKey("PK_DatabaseWrites", x => x.Id);
})
.Annotation("MySql:CharSet", "utf8mb4");
}
/// <inheritdoc />
protected override void Down(MigrationBuilder migrationBuilder)
{
migrationBuilder.DropTable(
name: "DatabaseWrites");
}
}
}

View File

@@ -0,0 +1,68 @@
// <auto-generated />
using System;
using Microsoft.EntityFrameworkCore;
using Microsoft.EntityFrameworkCore.Infrastructure;
using Microsoft.EntityFrameworkCore.Storage.ValueConversion;
using Modbus.Net.Modbus.Test;
#nullable disable
namespace Modbus.Net.Modbus.Test.Migrations
{
[DbContext(typeof(DatabaseWriteContext))]
partial class DatabaseWriteContextModelSnapshot : ModelSnapshot
{
protected override void BuildModel(ModelBuilder modelBuilder)
{
#pragma warning disable 612, 618
modelBuilder
.HasAnnotation("ProductVersion", "7.0.2")
.HasAnnotation("Relational:MaxIdentifierLength", 64);
modelBuilder.Entity("Modbus.Net.Modbus.Test.DatabaseWriteEntity", b =>
{
b.Property<int>("Id")
.ValueGeneratedOnAdd()
.HasColumnType("int");
b.Property<DateTime>("UpdateTime")
.HasColumnType("datetime(6)");
b.Property<double?>("Value1")
.HasColumnType("double");
b.Property<double?>("Value10")
.HasColumnType("double");
b.Property<double?>("Value2")
.HasColumnType("double");
b.Property<double?>("Value3")
.HasColumnType("double");
b.Property<double?>("Value4")
.HasColumnType("double");
b.Property<double?>("Value5")
.HasColumnType("double");
b.Property<double?>("Value6")
.HasColumnType("double");
b.Property<double?>("Value7")
.HasColumnType("double");
b.Property<double?>("Value8")
.HasColumnType("double");
b.Property<double?>("Value9")
.HasColumnType("double");
b.HasKey("Id");
b.ToTable("DatabaseWrites");
});
#pragma warning restore 612, 618
}
}
}

View File

@@ -7,6 +7,24 @@
<Nullable>enable</Nullable> <Nullable>enable</Nullable>
</PropertyGroup> </PropertyGroup>
<ItemGroup>
<None Remove="appsettings.json" />
</ItemGroup>
<ItemGroup>
<Content Include="appsettings.json">
<CopyToOutputDirectory>PreserveNewest</CopyToOutputDirectory>
</Content>
</ItemGroup>
<ItemGroup>
<PackageReference Include="Microsoft.EntityFrameworkCore.Design" Version="7.0.2">
<IncludeAssets>runtime; build; native; contentfiles; analyzers; buildtransitive</IncludeAssets>
<PrivateAssets>all</PrivateAssets>
</PackageReference>
<PackageReference Include="Pomelo.EntityFrameworkCore.MySql" Version="7.0.0" />
</ItemGroup>
<ItemGroup> <ItemGroup>
<ProjectReference Include="..\..\Modbus.Net\Modbus.Net.Modbus\Modbus.Net.Modbus.csproj" /> <ProjectReference Include="..\..\Modbus.Net\Modbus.Net.Modbus\Modbus.Net.Modbus.csproj" />
<ProjectReference Include="..\..\Modbus.Net\Modbus.Net\Modbus.Net.csproj" /> <ProjectReference Include="..\..\Modbus.Net\Modbus.Net\Modbus.Net.csproj" />

View File

@@ -1,8 +1,7 @@
// See https://aka.ms/new-console-template for more information // See https://aka.ms/new-console-template for more information
using Modbus.Net; using Modbus.Net;
using Modbus.Net.Modbus; using Modbus.Net.Modbus;
using Modbus.Net.Interface; using Modbus.Net.Modbus.Test;
using Modbus.Net.Job;
List<AddressUnit> _addresses = new List<AddressUnit> List<AddressUnit> _addresses = new List<AddressUnit>
{ {
@@ -20,7 +19,7 @@ List<AddressUnit> _addresses = new List<AddressUnit>
IMachine<string> machine = new ModbusMachine<string, string>("ModbusMachine1", ModbusType.Tcp, "192.168.0.172:502", _addresses, true, 1, 2, Endian.BigEndianLsb); IMachine<string> machine = new ModbusMachine<string, string>("ModbusMachine1", ModbusType.Tcp, "192.168.0.172:502", _addresses, true, 1, 2, Endian.BigEndianLsb);
await MachineJobSchedulerCreator.CreateScheduler(-1, 5).Result.From(machine.Id, machine, MachineDataType.Name).Result.Query("ConsoleQuery", QueryConsole).Result.To(machine.Id + ".To", machine).Result.Run(); await MachineJobSchedulerCreator.CreateScheduler("Trigger1", -1, 5).Result.From(machine.Id, machine, MachineDataType.Name).Result.Query("ConsoleQuery", QueryConsole).Result.To(machine.Id + ".To", machine).Result.Run();
Console.ReadLine(); Console.ReadLine();
@@ -29,6 +28,29 @@ Dictionary<string, ReturnUnit> QueryConsole(Dictionary<string, ReturnUnit> value
foreach (var value in values) foreach (var value in values)
{ {
Console.WriteLine(value.Key + " " + value.Value.DeviceValue); Console.WriteLine(value.Key + " " + value.Value.DeviceValue);
}
using (var context = new DatabaseWriteContext())
{
context.DatabaseWrites.Add(new DatabaseWriteEntity
{
Value1 = values["Test1"].DeviceValue,
Value2 = values["Test2"].DeviceValue,
Value3 = values["Test3"].DeviceValue,
Value4 = values["Test4"].DeviceValue,
Value5 = values["Test5"].DeviceValue,
Value6 = values["Test6"].DeviceValue,
Value7 = values["Test7"].DeviceValue,
Value8 = values["Test8"].DeviceValue,
Value9 = values["Test9"].DeviceValue,
Value10 = values["Test10"].DeviceValue,
UpdateTime = DateTime.Now,
});
context.SaveChanges();
}
foreach (var value in values)
{
value.Value.DeviceValue = new Random().Next(65536) - 32768; value.Value.DeviceValue = new Random().Next(65536) - 32768;
} }

View File

@@ -0,0 +1,8 @@
{
"ConnectionStrings": {
"DatabaseWriteConnectionString": "Server=localhost; User ID=root; Password=123456; Database=modbusnettest;"
},
"Config": {
"FetchSleepTime": "100"
}
}